screenshots
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
screenshots [2010/04/21 21:17] – created arnaud | screenshots [2015/01/11 21:43] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== Screenshots ====== | ====== Screenshots ====== | ||
- | Overview of oscopy after exec demo.oscopy | + | <columns 100% 30% -> |
- | {{:oscopy:capture-1.png|Overview | + | {{: |
+ | |||
+ | < | ||
+ | Overview of ioscopy | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{:ioscopy-gui.png? | ||
+ | < | ||
+ | The main window list the files (Readers) and their Signals currently managed by '' | ||
+ | |||
+ | Signals can be skipped during updated when the checkbox '' | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{:ioscopy-cursors.png?256|A figure window with Cursors and updated Signal}} | ||
+ | < | ||
+ | A Figure window. Here a copy of '' | ||
+ | < | ||
+ | vo=vout | ||
+ | oimport vo | ||
+ | ofreeze vo | ||
+ | </ | ||
+ | Then the capacitance C in the schematics | ||
+ | Cursor show the difference between both Signals. | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | The file menu. Read file, update Signals. | ||
+ | |||
+ | Scripts can be called also from here, as well as entering new math Signals. | ||
+ | |||
+ | **Main feature here: ** Run Netlister and Simulator from within ioscopy !! Once done, Signals will be automatically updated, considering dependencies ! | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | The window menu allow to raise windows that are closed. | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | Call third-party programs to generate ioscopy input files. | ||
+ | |||
+ | Can be toggled with the checkboxes. Settings are saved in '' | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | Figure window with contextual menu. From this menu, most Figure and Graph operations are accessible. | ||
+ | |||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | The layout menu to select the way graphs are organized in the window. | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | Scale menu. Pick one in Linear axis, Logarithmic axis or one Linear and one Log. | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | Insert a Signal directly from the contextual menu. | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | Remove a Signal from the Graph through the contextual menu. | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | Define the Graph limits. | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | Defines the Graph units and multipliers | ||
+ | </ | ||
+ | |||
+ | <columns 100% 30% -> | ||
+ | {{: | ||
+ | < | ||
+ | Select region for spanning | ||
+ | </ | ||
+ | |||
+ | ===== Integration with gschem, example ===== | ||
+ | Old IOscopy interface, but procedure still valid. | ||
Figure 3 before changing capacitance C in demo.sch | Figure 3 before changing capacitance C in demo.sch | ||
- | {{:oscopy: | + | |
+ | {{: | ||
Updating oscopy from within gschem | Updating oscopy from within gschem | ||
- | {{: | ||
- | Figure 3 after running netlister, simulator and updating results | + | {{: |
- | {{:oscopy: | + | |
+ | Figure 3 after running netlister, simulator and updating results | ||
+ | |||
+ | {{: |
screenshots.1271884657.txt.gz · Last modified: 2010/04/21 21:17 by arnaud